Skip to main content

Why Fusesaver™?

Overhead medium voltage networks must deliver reliable supply while controlling operating costs and managing safety risks. Faults on lateral lines are a major cause of outages and field interventions. Fusesaver™ addresses these challenges directly.

As the world’s fastest MV vacuum circuit breaker, Fusesaver clears faults in as little as half a cycle (10 ms), reducing the impact of transient faults and shortening outage durations. In fire risk areas, minimizing arc duration helps reduce the likelihood of fault related ignition. Its compact, lightweight design enables fast installation and commissioning.

The unique device is self-powered from line current and supports multi-phase fault clearing for both transient and permanent faults. Multiple operating modes (fuse saving, reclosing, sectionalizing and switching) allow utilities to deploy a single device consistently across different network applications.

Key benefits

Fast fault clearing for improved network reliability

Fusesaver clears faults in half a cycle (10 ms), reducing the impact of transient faults, shortening outage durations and limiting stress on network assets. Shorter arc duration also helps lower ignition risk in fire prone areas.

One device for multiple overhead network functions

Multiple operating modes (fuse saving, reclosing, sectionalizing, switching) allow utilities to use one device across diverse network scenarios, supporting standardization and adaptable protection strategies.

Less installation effort and ongoing operating costs

Compact, lightweight design enables fast installation, even remotely. Self-powered operation and optional remote access reduce site visits, enhancing asset management and lowering operating costs.

Featured capabilities

Bushfire mitigation - Fire risk reduction

To reduce bushfire risk on overhead networks, limiting arc duration during fault events is crucial, especially on extreme fire-risk days. Fusesaver clears faults in just 10 ms, significantly reducing arc energy. Its remote control allows reclosing inhibition from the control center, supporting bushfire mitigation while maintaining safe, reliable network operation.

Bushfire . Fire brigade fighting against

Discover how others use Fusesaver™

Frequently asked questions

Explore resources and related products

Watch

Case study | Powercor Australia minimizes fire risk 

Case study | Portable switch load and fault breaking 

Interview | Dr. Brett Watson

Read

Article | Enhancing lateral re-closer safety

Article | Asset selection in spur feeders 

Learn more

Catalog | Fusesaver™ 

Brochure | Fusesaver™ 

Flyer | Sectionalizing